Hotline: 0531-88759066
14753108565

Company News

Technological iteration and upgrading! The new nerve plexus stimulator achieves precise current regulation and control, enhancing the success rate of blockage

Updated:2026-04-28Click Count:0

The core pursuit of peripheral nerve block is "precise localization and efficient blockage". The precision of current regulation directly determines the accuracy of nerve localization and the effectiveness of blockage, and it is also the key to reducing clinical complications and enhancing patients' diagnostic and treatment experience. To address the industry pain points of insufficient current regulation precision and susceptibility to external interference in traditional nerve plexus stimulators, our company has continuously invested in technological research and development, completing a comprehensive iteration and upgrade of nerve plexus stimulators. The new nerve plexus stimulator, with its breakthrough current precision regulation technology, achieves dual improvements in localization precision and blockage success rate, providing more reliable technical support for clinical anesthesia and analgesia, and pushing the diagnostic and treatment level in the field of nerve regulation to a new level.

Traditional nerve plexus stimulators often adopt conventional current regulation modes, which suffer from issues such as low regulation accuracy, weak anti-interference capability, and insufficient parameter stability. In clinical operations, they are easily affected by factors such as changes in patient tissue impedance and electrode contact status, leading to fluctuations in output current and subsequently causing needle tip positioning deviations. This not only reduces the success rate of nerve block but may also damage nerves due to excessive current or fail to achieve precise positioning due to insufficient current, increasing the difficulty and clinical risks for medical staff. Addressing this core pain point, our R&D team has combined data from thousands of clinical cases to optimize circuit design and algorithm logic, creating a new type of nerve plexus stimulator with high-precision current regulation capability, achieving a technological leap from "coarse regulation" to "precise closed-loop regulation".

The core breakthrough of the new nerve plexus stimulator lies in its integration of an independently developed high-precision constant current regulation system. This system utilizes imported high-precision current sensors and intelligent feedback algorithms, enabling fine current adjustment down to the level of 0.01mA. The current output error is controlled within ±5%, significantly surpassing the industry's conventional standards. Compared to traditional devices, this system can monitor the dynamic changes in output current and tissue impedance in real-time. Through algorithms, it quickly corrects current deviations, ensuring that the output current remains stable regardless of tissue impedance fluctuations. This fundamentally solves the problem of inaccurate positioning caused by current fluctuations in traditional devices, making nerve positioning more precise and blocking more efficient.

In addition to precise current regulation capabilities, the new nerve plexus stimulator has undergone comprehensive optimization in terms of parameter adaptation and operational convenience. The device supports a wide range of current adjustment from 0.01 to 2.0 mA, paired with adjustable pulse widths from 0.05 to 1.0 ms. It allows for personalized setting of stimulation parameters according to the needs of different block sites and patient body types (such as children and obese patients), adapting to various peripheral nerve block scenarios such as brachial plexus, cervical plexus, and lumbar plexus, balancing universality and specificity. At the same time, the device is equipped with a high-definition LCD display, which can display core parameters such as current, pulse width, and impedance in real time. The operation interface is simple and intuitive, enabling medical staff to quickly get started, effectively improving clinical operation efficiency and reducing the rate of operational errors.

Clinical validation data reveals that the new nerve plexus stimulator, leveraging precise current regulation technology, has elevated the success rate of peripheral nerve block from approximately 80% with traditional devices to over 95%. This significant improvement notably diminishes the incidence of complications, such as repeated punctures and nerve damage, caused by positioning errors, reducing the complication rate by over 40%. Simultaneously, precise current regulation can decrease the dosage of local anesthetics, lower the risk of local anesthetic toxicity, alleviate postoperative pain in patients, shorten hospital stays, and align with the clinical principles of Enhanced Recovery After Surgery (ERAS). Consequently, it has garnered high acclaim from anesthesiologists and medical staff in several partner hospitals.

Technological innovation is the core driving force for enterprise development and the key to promoting the iteration and upgrading of medical equipment. The iteration and upgrading of the new nerve plexus stimulator not only demonstrates our company's technological accumulation and R&D strength in the field of neural regulation, but also reflects the product development philosophy of "being guided by clinical needs". In the future, our company will continue to focus on clinical pain points, increase investment in technological research and development, continuously optimize product performance, and promote technological innovation and upgrading of medical devices such as nerve plexus stimulators. With more precise, safer, and more efficient products, we aim to empower clinical anesthesia and analgesia diagnosis and treatment, safeguard patient safety, and contribute to the high-quality development of China's medical and health industry.

The content of this article is sourced from the internet, and the data information may not be accurate. It is for reference only

Back to List
  • Service Hotline 14753108565
    15665817873
    0531-88759066
  • Email

    3537028935@qq.com

Scan to Add WeChat

Copyright © 2026 Jinan Aobeikang Medical Technology Development Co., Ltd 鲁ICP备2024092603号-1 鲁公网安备37011202002228